CVE-2026-116606
🔴 High In CISA KEVBarracuda Email Security Gateway (ESG) only for this CVE, unlike its companion. Exploitation requires reaching the administration interface, so an appliance whose admin interface is not internet-facing is materially less exposed, which is Barracuda's own framing of the risk · ESG before 9.4.0.030
CVSS (Koffei note)
9.3CVSS (v4.0, CVE List)
9.3EPSS (2026-11-18)
10.947%95.97th percentile
CISA KEV
2026-11-10due 2026-11-13
Exploitation
Yes — CISA KEV since 10/11/2026, federal deadline 13/11/2026 (3 days, BOD 26-04); Barracuda said about a week after its 02/11/2026 disclosure that the flaws are exploited against a "small number of organizations", and Previdian observed 17 attempts against CVE-2026-116606 from 15 IPs in three countries between 09/11 and 11/11/2026 (SecurityWeek, 11/11/2026). This row is the authentication bypass, reached by restoring a crafted backup archive. Correction 11/11/2026: the row previously read "No — no exploitation known, not in CISA KEV" (SSVC of 02/11/2026); the KEV listing and vendor statement postdate that SSVC block. Red test met: confirmed exploitation dated 09-11/11/2026, inside 60 days. KEV status rests on SecurityWeek and SecurityOnline's write-up of CISA's alert, not on the CISA catalogue (unreachable). Daily CyberNews corroboration: 2026-11-11 Cybersecurity Watch. Previous text: No — no exploitation known, no public proof of concept, and not in CISA KEV (SSVC 02/11/2026: exploitation none, automatable yes, technical impact total). Barracuda reported it to Mandiant on 22/10/2026 and both advisories published 02/11/2026. The reason to weigh this above its 🟠 tier: Barracuda states that chained with CVE-2026-111560 it yields root on the appliance, and on ESG that chain begins with no credentials at all. The admin-interface precondition is therefore the control that decides exposure, not the patch level alone Rechecked on 09/11/2026: still no exploitation, still no public proof of concept and still outside CISA KEV ; SSVC unchanged at exploitation none. The row gains its first EPSS score. Rating unchanged at 🟠
Timeline
- 02/11/2026CVE record published (CVE List)
- 04/11/2026Barracuda — two flaws chainable to root
- 09/11/2026Barracuda ESG unauthenticated-to-root chain
- 10/11/2026Barracuda Email Security Gateway auth-bypass-to-root chain
- 10/11/2026Added to the CISA KEV catalogue
- 13/11/2026CISA deadline for US federal agencies
Risk
9.3 Critical (v4.0, Mandiant as CNA) — AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N, and CERT Santé scores it 9.8 on v3.1 — AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, so the two differ by scale rather than by judgement. EPSS 0.728% (54.23rd percentile, scored 03/11/2026). Mandiant rates exploitability high. (CWE-288 authentication bypass using an alternate path, CAPEC-115 : the configuration-import function can be invoked without authentication, so an unauthenticated remote attacker restores a crafted but system-compatible backup archive and rewrites the appliance's global configuration), EPSS 0.728% (54.45th percentile, scored 08/11/2026) — this row had no EPSS value at all until this recheck
Fix
Yes — ESG 9.4.0.030 or later, by patch BNSF-40425 for 9.4.017 and above or BNSF-40430 below 9.4.017 (Barracuda advisory, 02/11/2026). Workaround from CERT Santé until patched: restrict the administration interfaces to trusted internal networks and limit their exposure with network access controls. Detection, from Ostorlab, because neither Barracuda nor Mandiant has published indicators: review configuration-import and restore history for unexplained imports, diff the global configuration against a known-good backup, and review admin logs for sessions that reached admin functions with no matching successful login. Failed attempts may leave no trace at all
Official description
An authentication bypass in Barracuda Email Security Gateway versions earlier than 9.4.0.030 allows an unauthenticated remote attacker to invoke a configuration-import function and restore a crafted, compatible backup archive, resulting in unauthorized modification of the appliance’s global configuration.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CWE-288